 Multi-Output HP6 Front End and RACK-HP600 Data Sheet
HP6 Multi-Output AC-DC Front End
HP6 and RACK-HP600 Features * Compact 1U design * N+1 redundancy with hot plug capability * Up to four individually regulated outputs * I2C interface with interrupt capability * Hot swap with low insertion/extraction force connector * Power factor corrected * No minimum load required * 5 V @ 1 A standby output * Single-wire current sharing * Self-contained ORing Diodes * Current limit and over-voltage protection * Full power up to 50 C * TUV, cTUVus & CB report * 600 watts per module * Ac input with PFC
RACK-HP600 Description The HP6 provides up to 600 Watts total output power with one to four outputs ranging from 0.8 to 12 Volts. HP600 RACKS offer hot-plug capability for up to 1200 Watts total at low line (2 +1) or 1800 Watts total at high line. Three separate multi output power supplies are internally paralleled and will automatically current share for load distribution. Hot-swap modules can be replaced with no system downtime.
V1 HP6 Front End Models HP6-X8X8D2D-O HP6-X4X8D4D-O HP6-X8X4D4D-O HP6-X8X4D2D-O HP6-X4X8D2D-O HP6-X4X4D4D-O RACK-HP600 Designations RACK-HP600 Volts X X X X X X Amps 80 40 80 80 40 40 Volts X X X X X X
V2 Amps 80 80 40 40 80 40 Volts 12 12 12 12 12 12
V3 Amps 20 40 40 20 20 40
Volts -12 -12 -12 -12 -12 -12
V4 Amps 3 3 3 3 3 3
X
240
X
120
12
120
-12
9
Output Voltage X = A (2.0V); B (3.3V); C (5V); T (2.5V); V (1.8V); W (1.5V); X (1.2V); Y (1V); Z (0.8V) 2 Options O = B (I C); M (Output power good - TTL high); N (Power fail - TTL high); R (Reverse airflow) Please contact Power-One for additional model combinations.
Nov 7, 2006
Page 1 of 4
www.power-one.com
Multi-Output HP6 Front End and RACK-HP600 Data Sheet
Input Specifications
Input voltage range: 85 to 264 Vac, 47 to 63 Hz Power Factor: 0.99 at full load and nominal line Inrush Current: 40 A peak hot and cold start Input Protection: Internal 15 A line fuse
Signals and Controls
LED Output Good Indicator: Front panel green LED indicates power supply is good; amber indicates fault. LED AC Good Indicator: Front panel green LED indicates Ac input voltage is present and above minimum level. Output Good Signal*: TTL compatible signal, normally high. Goes low when power supply is out of specified range. Power Fail Signal*: TTL compatible signal, normally high (indicating Vin is present and above minimum level). Enable*: Normally TTL High, drive low to enable. *All interface signals are TTL compatible
Output Specifications
Output Power: 600 W maximum Overshoot/Undershoot: Less than 1% at turn-on or turnoff. Less than 3% for 50% to 100% load step. Start-Up Time: Less than 2 seconds Efficiency: 78% typical measured at full load, nominal input Hold-up Time: 20 ms minimum at full load and low line Single Wire Current Share (V1, V2 and +12V): 10% full load rating. Load Regulation: 0.5% with remote sense, 2% without Line Regulation: 0.1% over entire operating range Cross Regulation: Less than 0.5% Minimum Load: No minimum load required Overcurrent Protection: All outputs set to 115-135% of full rated load with automatic recovery Overtemperature Protection: Automatic shutdown with auto recovery. Remote Sense: Compensates for voltage drop of up to 0.5 V to the load (V1, V2, and +12V). Shorted sense lead protection. Overvoltage Protection: All outputs set at 115%-135% of nominal. Reset by cycling input power. Output Noise and Ripple: PARD: 1% or 50 mV p-p, whichever is greater, measured at 20 Mhz bandwidth.
I2C Interface
Event Driven Messages: * Notification of fan speed abnormality * Output voltage under specified `good' range * Output voltage over specified `good' range (software OVP) * Temperature abnormalities Sensor Device Commands: * Get voltage readings * Get temperature readings * Get fan speed readings FRU (Field Replaceable Unit) Information Storage: * Manufacturer's name * Product name * Product part/model number * Product version/revision * Product serial number
Safety & Environmental
Operating Temperature: 0 to 50C Storage Temperature: -40C to +85C Operating Humidity: Maximum 95% RH non-condensing Operating Altitude: 10,000 feet Non-operating Altitude: 40,000 feet Temperature Coefficient: 0.02% per C within rated load Safety Agency Compliance: TUV, cTUVus & CB report EMI: Meets EN55022, Class B Harmonic Suppression: Meets EN6100-3-2 Input Transient Protection: Electrostatic Discharge: EN61000-4-2, Criteria B Radiated, Radio-Frequency, Electromagnetic Field: EN61000-4-3, Criteria A Electrical Fast Transients/Burst: EN61000-4-4, Criteria B Voltage Fluctuations and Flickers: EN61000-3-3, Criteria B Surge Test: EN61000-4-5, Criteria B Conducted Immunity: EN61000-4-6, Criteria A Dielectric Withstand: Input-to-ground: 2200 Vdc Input-to-output: 4300 Vdc Output-to-case: 25 Vdc Ac Leakage Current: 1.2mA maximum at 240 Vac, 50 Hz
Mechanical Specifications
Size: 1.6" H x 5" W x 11.5" D Input Connector: Front panel IEC Output Connector: FCI power blade MTBF: 250,000 hours calculated at 25 C, Bellcore Standard Warranty: Two years from date of shipment, standard product only. Specifications are subject to change without prior notice.
Nov 7, 2006
Page 2 of 4
www.power-one.com
Multi-Output HP6 Front End and RACK-HP600 Data Sheet
HP6 Outline Drawings and Dimensions
HP6 Connector Pin Descriptions
HP6 PIN Numbers and Signal Names 1 Ground 2 Ground 3 V2 Output 4 V2 Output 5 V2 Output 6 Ground 7 Ground 8 Ground 9 V1 Output 10 V1 Output 11 V1 Output 12 Dc Enable 13 A1 14 -Sense 15 +Sense V1 16 V4 Output (-12V) 17 V4 Output (-12V) 18 Share V2 19 +Sense V2 20 SDA 21 SCL 22 Share V3 23 Power Fail OK 24 5V Standby 25 5V Standby 26 +Sense V3 27 Power OK 28 Present 29 A0 30 Interrupt 31 Share V1 32 Ground 33 V3 Output (+12V) 34 V3 Output (+12V)
HP6 J5 Connector Detail
Nov 7, 2006
Page 3 of 4
www.power-one.com
Multi-Output HP6 Front End and RACK-HP600 Data Sheet
RACK-HP600 Outline Drawings and Dimensions
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice.
Nov 7, 2006
Page 4 of 4
www.power-one.com


▲Up To Search▲   

 
Price & Availability of HP6-X8X4D4D-O

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X